-2

shows the example of a RAID 50 span with three RAID 5 arrays of different sizes. (Each array can have from three to 14 hard disks.) Data is striped

across the three RAID 5 arrays until the smallest array is full. The data is striped across the remaining two RAID 5 arrays until the smaller of the two arrays is
full. Finally, data is stored in the additional space in the largest array.

Figure 4-2. Storage in a RAID 50 Array

 

 

Performance Considerations

 

The system performance improves as the number of spans increases. As the storage space in the spans is filled, the system stripes data over fewer and fewer
spans and RAID performance degrades to that of a RAID 1 or RAID 5 array.

 

Optimizing Storage

 

Data Access Requirements

 

Each type of data stored in the disk subsystem has a different frequency of read and write activity. If you know the data access requirements, you can more
successfully determine a strategy for optimizing the disk subsystem capacity, availability, and performance.

 

Servers that support video on demand typically read the data often, but write data infrequently. Both the read and write operations tend to be long. Data
stored on a general-purpose file server involves relatively short read and write operations with relatively small files.

 

Array Functions

 

Define the major purpose of the disk array by answering questions such as the following, which are followed by suggested RAID levels for each situation:

l

 

Will this disk array increase the system storage capacity for general-purpose file and print servers? Use RAID 5, 10, or 50.

l

 

Does this disk array support any software system that must be available 24 hours per day? Use RAID 1, 5, 10, or 50.

l

 

Will the information stored in this disk array contain large audio or video files that must be available on demand? Use RAID 0.

l

 

Will this disk array contain data from an imaging system? Use RAID 0 or 10.

 

Planning the Array Configuration

 

Fill out

Table 4

-8

to help you plan the array configuration. Rank the requirements for your array, such as storage space and data redundancy, in order of

importance, then review the suggested RAID levels. Refer to

Table 4

-7

for the minimum and maximum number of drives allowed per RAID level.

 

 

Table 4-8. Factors to Consider for Array Configuration 