Step 2 power down the system, Step 3 set jumpers – Dell PERC 4/DC User Manual

Page 55

Advertising
background image

 

Unpack and remove the controller and inspect it for damage. If the controller appears damaged, or if any items listed below are missing, contact your Dell
support representative. The RAID controller is shipped with:

l

 

The PERC 4 RAID Controller User's Guide (on CD)

l

 

The CERC and PERC RAID Controllers Operating System Driver Installation Guide (on CD)

 

l

 

A license agreement

 

Step 2 Power Down the System

 

Perform the following steps to power down the system:

1.

 

Turn off the system.

2.

 

Remove the AC power cord.

3.

 

Disconnect the system from any networks before installing the controller.

4.

 

Remove the system's cover.

 

Please consult the system documentation for instructions.

 

Step 3 Set Jumpers

 

Make sure the jumper settings on the RAID controller are correct. Following are diagrams of the controllers showing their jumpers and connectors, and tables
describing them. Select your controller from the ones shown on the following pages.

 

PERC 4/SC Jumpers and Connectors

Figure 3-1. PERC 4/SC Controller Layout

 

 

 

Table 3-1. PERC 4/SC Jumper and Connector Descriptions 

NOTICE:

See the safety instructions in your system documentation for information about protecting against electrostatic discharge.

NOTE:

You can order a hard copy of the documentation for the controller.

Connector Description

Type

Setting

 

J1

 

Internal SCSI connector

 

68-pin

connector

 

Internal high-density SCSI bus connector.

Connection is optional.

 

J2

 

NVRAM Clear

 

2-pin header

 

To CLEAR configuration data, install a jumper.

 

J3

 

Serial EPROM

 

2-pin header

 

To CLEAR configuration data, install a jumper.

 

J4

 

Onboard BIOS Enable

 

2-pin header

 

No jumper = Enabled (Default is Enabled)

Advertising
This manual is related to the following products: