Step 4 Install the RAID Controller

 

Perform the following steps to install the controller:

1.

 

Select a 3.3-V PCI slot and align the controller PCI bus connector to the slot.

2.

 

Press down gently but firmly to make sure that the controller is properly seated in the slot, as shown in

Figure 3

-3

.

3.

 

Screw the bracket to the system chassis.

Figure 3-3. Inserting the RAID Controller into a PCI Slot

 

 

Step 5 Connect SCSI Cables and SCSI Devices

 

Connect the SCSI cables to the SCSI connectors and SCSI devices.

 

Connect SCSI Devices

 

Perform the following steps to connect SCSI devices.

1.

 

Disable termination on any SCSI device that does not sit at the end of the SCSI bus.

2.

 

Configure all SCSI devices to supply TermPWR..

3.

 

Set proper target IDs (TIDs) for all SCSI devices.

Pin-2 TXD (Transmit Data)
Pin-3 GND (Ground)

 

J16

 

Onboard BIOS Enable

 

2-pin header

 

No jumper = Enabled (Default setting)

Jumpered = Disabled

 

J17

 

TERMPWR Enable Channel 0

 

2-pin header

 

Jumper installed enables TERMPWR from the PCI bus. Default setting.

 

No jumper installed enables TERMPWR from the SCSI bus. (See J4 and J5)

 

J18

 

TERMPWR Enable Channel 1

 

2-pin header

 

J19

 

External SCSI Channel 1

connector

 

68-pin

connector

 

External very-high density SCSI bus connector. Connection is optional.

 

J23

 

Serial EEPROM

 

2-pin header

 

To CLEAR configuration data, install a jumper.

 

D17 - D24  LED (located on back of card)

  

 

Indicate problems with the card.