Dell PERC 4/DC User Manual

Page 56

Advertising
background image

 

PERC 4/DC Jumpers and Connectors

Figure 3-2. PERC 4/DC Controller Layout

 

 

 

Table 3-2. PERC 4/DC Jumper and Connector Descriptions 

With jumper in = Disabled

 

J5

 

SCSI Activity

 

2-pin header

 

Connector for enclosure LED to indicate data transfers. Connection is optional.

 

J6

 

Serial Port

 

3-pin header

 

Connector is for diagnostic purposes.

Pin-1 RXD (Receive Data)
Pin-2 TXD (Transmit Data)
Pin-3 GND (Ground)

 

J7

 

External SCSI connector

 

68-pin

connector

 

External very-high density SCSI bus connector.

Connection is optional.

 

J9

 

SCSI bus TERMPWR Enable

 

2-pin header

 

Install jumper to enable onboard termination power. Default is installed.

 

J10

 

SCSI bus Termination

Enable

 

3-pin header

 

Jumper pins 1-2 to enable software control of SCSI termination through drive detection.

 

Jumper pins 2-3 to disable onboard SCSI termination.

 

Having no jumper installed enables onboard SCSI termination. The default is no jumper

installed.

 

D12 - D19  LEDs

   

 

Indicate problems with the card.

Connector Description

Type

Settings

 

J1

 

I2C Header

 

4-pin header

 

Reserved.

 

J2

 

SCSI Activity LED

 

4-pin header

 

Connector for LED on enclosure to indicate data transfers. Optional.

 

J3

 

Write Pending Indicator

(Dirty Cache LED)

 

2-pin header

 

Connector for enclosure LED to indicate when data in the cache has yet to be written to the

device. Optional.

 

J4

 

SCSI Termination Enable

Channel 1

 

3-pin header

 

Jumper pins 1-2 to enable software control of SCSI termination via drive detection.

 

Jumper pins 2-3 to disable onboard SCSI termination.

 

No Jumper installed enables onboard SCSI termination. (See J17 and J18). The default is no

jumper installed.

 

J5

 

SCSI Termination Enable

Channel 0

 

3-pin header

 

J6

 

DIMM socket

 

DIMM socket

 

Socket that hold the memory module

 

J7

 

Internal SCSI Channel 0

connector

 

68-pin

connector

 

Internal high-density SCSI bus connector. Connection is optional.

 

J8

 

Internal SCSI Channel 1

connector

 

68-pin

connector

 

J9

 

External SCSI Channel 0

connector

 

68-pin

connector

 

External very-high density SCSI bus connector. Connection is optional.

 

J10

 

Battery connector

 

3-pin header

 

Connector for an optional battery pack.

Pin-1 -BATT Terminal (black wire)
Pin-2  Thermistor (white wire)
Pin-3 +BATT Terminal (red wire)

 

J11

 

NVRAM clear

 

2-pin header

 

To CLEAR the configuration data, install a jumper.

 

J12

 

NMI jumper

 

2-pin header

 

Reserved for factory.

 

J13

 

32-bit SPCI Enable

 

3-pin header

 

Reserved for factory.

 

J14

 

Mode Select jumper

 

2-pin header

  

 

J15

 

Serial Port

 

3-pin header

 

Connector is for diagnostic purposes.

Pin-1 RXD (Receive Data)

Advertising