Raid management utilities, Bios configuration utility, Dell manager – Dell PERC 4/DC User Manual

Page 8: Dell openmanage array manager, Server administrator storage management service

Advertising
background image

The RAID controller firmware handles all RAID and SCSI command processing and supports the features described in

Table 2

-8

.

 

 

Table 2-8. SCSI Firmware Support 

 

RAID Management Utilities

 

Software utilities enable you to manage and configure the RAID system, create and manage multiple disk arrays, control and monitor multiple RAID servers,
provide error statistics logging, and provide online maintenance. The utilities include:

l

 

BIOS Configuration Utility

l

 

Dell Manager for Linux

l

 Dell OpenManage™ Array Manager for Windows and Netware 

 

BIOS Configuration Utility

 

The BIOS Configuration Utility configures and maintains RAID arrays, clears hard drives, and manages the RAID system. It is independent of any operating
system. See

BIOS Configuration Utility and Dell Manager

for additional information.

 

Dell Manager

 

Dell Manager is a utility that works in Red Hat Linux. See

BIOS Configuration Utility and Dell Manager

for additional information.

 

Dell OpenManage Array Manager

 

Dell OpenManage Array Manager is used to configure and manage a storage system that is connected to a server, while the server is active and continues to
handle requests. Array Manager runs under Novell NetWare, Windows 2000, and Windows Server 2003. Refer to the online documentation that accompanies
Array Manager or the documentation section at

support.dell.com

for more information.

 

 

Server Administrator Storage Management Service

 

Storage Management provides enhanced features for configuring a system's locally attached RAID and non-RAID disk storage. Storage Management runs
under Red Hat Linux, Windows 2000, and Windows Server 2003. Refer to the online documentation that accompanies Storage Management or the
documentation section at

support.dell.com

for more information.

Back to Contents Page

 

Feature

PERC 4/SC, PERC 4/DC, and PERC 4e/DC Description

 

Disconnect/reconnect

 

Optimizes SCSI bus utilization

 

Tagged command queuing  Multiple tags to improve random access

 

Multi-threading

 

Up to 255 simultaneous commands with elevator sorting and concatenation of requests per SCSI channel

 

Stripe size

 

Variable for all logical drives: 8 KB, 16 KB, 32 KB, 64 KB, or 128 KB.

 

Rebuild

 

Multiple rebuilds and consistency checks with user-definable priority.

NOTE:

You can run the OpenManage Array Manager remotely to access NetWare, but not locally.