Hardware architecture features, Array performance features, Drive migration – Dell PERC 4/DC User Manual

Page 6: Led operation

Advertising
background image

Drive roaming occurs when the hard drives are changed to different channels on the same controller. When the drives are placed on different channels, the
controller detects the RAID configuration from the configuration information on the drives.

 

Configuration data is saved in both non-volatile random access memory (NVRAM) on the RAID controller and on the hard drives attached to the controller. This
maintains the integrity of the data on each drive, even if the drives have changed their target ID. Drive roaming is supported across channels on the same
controller, except when cluster mode is enabled.

 

 

 

Table 2

-4

lists the drive roaming features for the RAID controller.

 

 

Table 2-4. Features for Drive Roaming

 

Drive Migration

 

Drive migration is the transfer of a set of hard drives in an existing configuration from one controller to another. The drives must remain on the same channel
and be reinstalled in the same order as in the original configuration.

 

 

Hardware Architecture Features

 

Table 2

-5

displays the hardware architecture features for the RAID controller.

 

 

Table 2-5. Hardware Architecture Features 

 

LED Operation

 

After you remove a physical drive and place it back in the slot for a rebuild, the LED blinks for the drive as it is being rebuilt.

 

NOTE:

Drive roaming does not work if you move the drives to a new controller and put them on different channels. If you put drives on a new controller,

the controller must have a clear configuration. In addition, the drives must be on the same channel/target as they were on the previous controller to
keep the same configuration.

NOTE:

Before performing drive roaming, make sure that you have first powered off both your platform and your drive enclosure.

Specification

PERC 4/SC PERC 4/DC PERC 4e/DC

 

Online RAID level migration

 

Yes

 

Yes

 

Yes

 

RAID remapping

 

Yes

 

Yes

 

Yes

 

No reboot necessary after capacity extension  Yes

 

Yes

 

Yes

NOTE:

Drive roaming and drive migration cannot be supported at the same time. PERC can support either drive roaming or drive migration at any one

time, but not both at the same time.

Specification

PERC 4/SC

PERC 4/DC

PERC 4e/DC

 

Processor

 

Intel GC80302 (Zion Lite)

 

Intel GC80303 (Zion)

 

80332

 

SCSI controller(s)

 

One LSI53C1020 Single SCSI

controller

 

One LSI53C1030 Dual SCSI

controller

 

One LSI53C1030 Dual SCSI

controller

 

Size of flash memory

 

1 MB

 

1 MB

 

1 MB

 

Amount of NVRAM

 

32 KB

 

32 KB

 

32 KB

 

Hardware exclusive OR (XOR) assistance

 

Yes

 

Yes

 

Yes

 

Direct I/O

 

Yes

 

Yes

 

Yes

 

SCSI bus termination

 

Active or LVD

 

Active or LVD

 

Active or LVD

 

Double-sided dual inline memory modules (DIMMs)

 

Yes

 

Yes

 

Yes

 

Support for hard drives with capacities of more than

eight gigabytes (GB)

 

Yes

 

Yes

 

Yes

 

Hardware clustering support on the controller

 

No

 

Yes

 

Yes

Advertising