Hardware Installation

Dell™ PowerEdge™ Expandable RAID Controller 4/SC, 4/DC, and 4e/DC User's Guide

  

Requirements

  

Quick Installation Procedure

  

Installation Steps

 

Requirements

 

This section describes the procedures for installing the RAID controller. You must have the following items to install the controller:

l

 

A PERC 4/SC, 4/DC, or 4e/DC controller

l

 

A host system with an available 32- or 64-bit, PCI extension slot for PERC 4/SC or 4/DC, and a PCI-Express slot for PERC 4e/DC

l

 

The Dell OpenManage™ Systems Management CD or driver diskette

l

 

The necessary internal and/or external SCSI cables

l

 

Ultra, Ultra2, Ultra3, Ultra160, or Ultra320 SCSI hard drives

(SCSI is backward compatible, but it slows to the speed of the slowest device).

 

Quick Installation Procedure

 

Perform the following steps for quick installation of the controller if you are an experienced system user/installer. All others should follow the steps in the next
section,

Installation Steps

.

 

1.

 

Turn off all power to the server and all hard drives, enclosures, and system components, then disconnect power cords from the system.

2.

 

Open host system by following the instructions in the host system technical documentation.

3.

 

Determine the SCSI ID and SCSI termination requirements.

 

4.

 

Install the PERC 4/SC or 4/DC RAID controller in a PCI slot or the PERC 4e/DC in the PCI- Express slot in the server and attach the SCSI cables and

terminators.

 

See the section

Cable Suggestions

for cable information and suggestions.

l

 

Make sure pin 1 on the cable matches pin 1 on the connector.

l

 

Make sure that the SCSI cables conform to all SCSI specifications.

5.

 

Perform a safety check.

l

 

Make sure all cables are properly attached.

l

 

Make sure the RAID controller is properly installed.

l

 

Close the cabinet of the host system.

l

 

Turn power on after completing the safety check.

6.

 

Format the hard drives as needed.

7.

 

Configure logical drives using the BIOS Configuration Utility or Dell Manager.

8.

 

Initialize the logical drives.

9.

 

Install the network operating system drivers as needed.

 

CAUTION:

See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting

against electrostatic discharge.

NOTE:

The default for SCSI termination is onboard SCSI termination enabled. See the section

Step 7 Set SCSI Termination

for a description of SCSI

termination.