Scsi cable and connector problems, Audible warnings – Dell PERC 4/DC User Manual

Page 85

Advertising
background image

See

RAID Controller Features

for information about the jumper to set to clear NVRAM.

l

 

Make sure that the configuration data on the disks is intact.

l

 

Transfer the cache to the new controller and connect the drives in the same order as they were connected on the previous adapter.

 

This ensures that the configuration data on the cache matches the configuration data on they physical disks. This is important for successful cache
migration.

l

 

Power on the system.

 

SCSI Cable and Connector Problems

 

If you are having problems with your SCSI cables or connectors, first check the cable connections. If still having a problem, visit the Dell's web site at

www.dell.com

for information about qualified small computer system interface (SCSI) cables and connectors or contact your Dell representative for information.

 

Audible Warnings

 

The RAID controller has a speaker that generates warnings to indicate events and errors.

Table 6

-4

describes the warnings.

 

 

Table 6-4. Audible Warnings 

Back to Contents Page

 

Tone Pattern

Meaning

Examples

 

Three seconds on and one

second off

 

A logical drive is offline.

 

One or more drives in a RAID 0 configuration failed.

 

Two or more drives in a RAID 1 or 5 configuration failed.

 

One second on and one

second off

 

A logical drive is running in degraded

mode.

 

One drive in a RAID 5 configuration failed.

 

One second on and three

seconds off

 

An automatically initiated rebuild has been

completed.

 

While you were away from the system, a hard drive in a RAID 1 or 5

configuration failed and was rebuilt.

Advertising
This manual is related to the following products: