background image

Error Code Message Information

AMP0302

Message

The system board <

name

> current is greater than the upper warning threshold.

Details

System board <

name

> current is outside of the optimum range.

Action

1. Review system power policy.
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see

Getting Help

.

AMP0303

Message

The system board <

name

> current is greater than the upper critical threshold.

LCD Message

System board <

name

> current is outside of range.

Details

System board <

name

> current is outside of the optimum range.

Action

1. Review system power policy.
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see

Getting Help

.

ASR0000

Message The watchdog timer expired.

Details

The operating system or an application failed to communicate within the time-out period.

Action

Check the operating system, application, hardware, and system event log for exception
events.

ASR0001

Message The watchdog timer reset the system.

Details

The operating system or an application failed to communicate within the time-out
period. The system was reset.

Action

Check the operating system, application, hardware, and system event log for exception
events.

ASR0002

Message The watchdog timer powered off the system.

Details

The operating system or an application failed to communicate within the time-out
period. The system was shut down.

Action

Check the operating system, application, hardware, and system event log for exception
events.

ASR0003

Message The watchdog timer power cycled the system.

Details

The operating system or an application failed to communicate within the time-out
period. The system was power-cycled.

Action

Check the operating system, application, hardware, and system event log for exception
events.