Error Code Message Information

Action

Check the event log for power supply failures. Review system configuration and power
consumption and upgrade or install power supplies accordingly.

PWR1005

Message The system performance degraded because the user-defined power capacity has changed.

Details

The user-defined power settings have affected system operation.

Action

If unintended, review system configuration changes and power policy.

PWR1006

Message

The system halted because system power exceeds capacity.

LCD Message System power demand exceeds capacity. System halted.

Details

The system halted because system power exceeds capacity.

Action

Review system configuration, upgrade power supplies or reduce system power
consumption.

RFM1008

Message

Failure detected on Removable Flash Media <

name

>.

LCD Message

Removable Flash Media <

name

> failed. Check SD Card.

Details

An error was reported during a SD card read or write.

Action

Reseat the flash media. If the problem persists, see

Getting Help

.

RFM1014

Message

Removable Flash Media <

name

> is write protected.

LCD Message Removable Flash Media <

name

> is write protected. Check SD Card.

Details

The card is write-protected by the physical latch on the SD card. A write-protected
card cannot be used.

Action

If unintended, remove the media and disable write protection.

RFM1201

Message

Internal Dual SD Module redundancy is lost.

LCD Message

Internal Dual SD Module redundancy is lost. Check SD Card.

Details

Either one or both the SD cards are not functioning properly.

Action

See

Getting Help

.

RFM2001

Message

Internal Dual SD Module <

name

> is absent.

LCD Message

Internal Dual SD Module <

name

> is absent. Check SD Card.

Details

The SD card module is not detected or not installed.

Action

If unintended, reinstall the SD module.

RFM2002

Message Internal Dual SD Module <

name

> is offline.

Details

The SD card module is installed but may be improperly installed or configured incorrectly.

128