Error Code Message Information

Action

Remove and re-seat the failed disk. If the issue persists, see

Getting Help

.

PDR1016

Message

Drive <

number

> is removed from disk drive bay <

bay

>.

LCD Message Drive <

number

> removed from disk drive bay <

bay

>. Check drive.

Details

The controller detected that the drive was removed.

Action

Verify drive installation. Re-seat the failed drive. If the issue persists, see

Getting Help

.

PST0128

Message

No memory is detected.

LCD Message

No memory is detected. Inspect memory devices.

Details

System BIOS was unable to detect memory in the system.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

PST0129

Message

Memory is detected, but is not configurable.

LCD Message Memory is detected, but is not configurable. Check memory devices.

Details

System BIOS detected memory, but was unable to configure the memory for system
operation.

Action

Compare system memory installation to supported system memory configurations.

PSU0001

Message

Power supply <

number

> failed.

LCD Message

PSU <

number

> failed. Check PSU.

Action

Remove and reinstall the power supply. If the issue persists, see

Getting Help

.

PSU0002

Message

A predictive failure detected on power supply <

number

>.

LCD Message Predictive failure on PSU <

number

>. Check PSU.

Details

System performance and power redundancy may be degraded or lost.

Action

Remove and reinstall the power supply at the next service window. If the issue persists,
see

Getting Help

.

PSU0003

Message

The power input for power supply <

number

> is lost.

LCD Message Power input for PSU <

number

> is lost. Check PSU cables.

Details

The power supply is installed correctly but an input source is not connected or is not
functional.

Action

Verify the input source is attached to the power supply. Verify the input power is within
the operating requirements for the power supply.

PSU0006

Message

Power supply <

number

> type mismatch.

125