Default management port settings – Dell PowerVault MD3220i User Manual

Page 56

Advertising
background image

56

Appendix—Manual Configuration of iSCSI

Step 1: Discover the Storage Array (Out-of-band

Management Only)

Default Management Port Settings

By default, the storage array management ports are set to Dynamic Host

Configuration Protocol (DHCP). If the controllers on your storage array are

unable to get IP configuration from a DHCP server, it times out after 10

seconds and falls back to a default static IP address. The default IP

configuration is:

Controller 0: IP: 192.168.128.101 Subnet Mask:

255.255.255.0

Controller 1: IP: 192.168.128.102 Subnet Mask:

255.255.255.0

NOTE:

No default gateway is set.

NOTE:

If DHCP is not used, initial configuration using the management station must

be performed on the same physical subnet as the storage array. Additionally, during

initial configuration, at least one network adapter must be configured on the same

IP subnet as the storage array’s default management port (192.168.128.101 or

192.168.128.102). After initial configuration (management ports are configured using

PowerVault MD Storage Manager), the management station’s IP address can be

changed back to its previous settings.

NOTE:

This procedure applies to out-of-band management only. If you choose to

set up in-band management, you must complete this step and then see "Step 8:

(Optional) Set Up In-Band Management" on page 74.

You can discover the storage array either automatically or manually. Select

one and complete the steps below.

book.book Page 56 Sunday, September 11, 2011 10:24 PM