Step 4: configure host access, Step 4: configure host – Dell PowerVault MD3220i User Manual

Page 62

Advertising
background image

62

Appendix—Manual Configuration of iSCSI

c

Verify that the following time-out value is set to 30:
node.session.timeo.replacement_timeout = 30

d

Save and close the /etc/iscsi/iscsid.conf file.

5 From the console, restart the iSCSI service with the following command:

service iscsi start

6 Verify that the iSCSI service is running during boot using the following

command from the console:

chkconfig iscsi on

7 To display the available iSCSI targets at the specified IP address, use the

following command:

iscsiadm –m discovery –t st -p

<IP_address_of_iSCSI_port>

8 After target discovery, use the following command to manually log in:

iscsiadm -m node –l

This log in is performed automatically at startup if automatic startup is

enabled.

9 Manually log out of the session using the following command:

iscsiadm -m node -T <initiator_username> -p

<target_ip> -u

Step 4: Configure Host Access

This step specifies which host servers access virtual disks on the storage array.

You should perform this step:

• Before mapping virtual disks to host servers
• Any time you connect new host servers to the storage array

1 Launch MDSM.
2 Navigate to the AMW and click Manually define hosts.
3 At Enter host name, enter the host server for virtual disk mapping.

This can be an informal name, not necessarily a name used to identify the

host server to the network.

4 Select a method for adding the host port identifier.

book.book Page 62 Sunday, September 11, 2011 10:24 PM