Fax settings – Dell C3765dnf Color Laser Printer User Manual

Page 249

Advertising
background image

Understanding the Printer Menus

247

IP Filter

NOTE:

IP Filter feature is available only for

LPD

or

Port9100

.

Purpose:
To block data received from certain IP addresses through the wired or wireless network. You can set up to five IP

addresses. The change becomes effective after the printer is turned off and then on again.
Values:

IEEE 802.1x

NOTE:

IEEE 802.1x feature is available only when the printer is connected using Ethernet cable and it is available only when the

IEEE 802.1x authentication is enabled.

Purpose:
To disable IEEE 802.1x authentication. The change becomes effective after the printer is turned off and then on

again.

Adobe Protocol

Purpose:
To specify PostScript communication protocol for a parallel interface, you can configure the Adobe Protocol

settings for the wired network. The change becomes effective after the printer is turned off and then on again.
Values:

Reset LAN

Purpose:
To initialize wired network data stored in non-volatile memory (NVM). After executing this function and rebooting

the printer, all wired network settings are reset to their default values.

Fax Settings

Use the Fax Settings menu to configure the basic fax settings.

NOTE:

Values marked by an asterisk (*) are the factory default menu settings.

Fax Line Settings

Purpose:
To configure basic settings for the fax line.

n (n is 1-5)

IP Address

Sets the IP address for Filter n.

Subnet Mask

Sets the address mask for Filter n.

Mode

Off

*

Disables the IP Filter feature for Filter n.

Accept

Accepts an access from the specified IP address.

Reject

Rejects an access from the specified IP address.

Auto

*

Used when auto-detecting the PostScript communication protocol.

Standard

Used when the communication protocol is in ASCII interface.

BCP

Used when the communication protocol is in binary format.

TBCP

Used when the communication protocol supports both ASCII and binary data to switch

between them according to the specified control code.

Binary

Used when no special processing is required for data.