Configuring and Managing RAID

Performing the Replace Member operation

Setting the LED to blink

Making a disk online or offline (unaffiliated with a disk group)

Creating global hot spares

Removing dedicated hot spares or global hot spares

Physical Disk Actions

Table 6-5 describes the actions you can perform on physical disks.
For procedures that can be used to perform these actions, see "Physical Disk
Management" on page 105.

Table 6-5.

Physical Disk Actions

Action

Description

Rebuild

Regenerates all data to a replacement disk in a redundant
virtual disk (RAID level 1, 5, 6, 10, 50, or 60) after a disk
failure. A disk rebuild normally occurs without interrupting
normal operations on the affected virtual disk.

Replace Member

Replaces the drive in the virtual disk with another drive that
can be selected.

LED Blinking

Indicates when physical disks are being used to create a virtual
disk. You can choose to start or stop the LED blinking.

Force Online

Changes the state of the selected physical disk to online.

Force Offline

Changes the state of the selected physical disk so that it is no
longer part of a virtual disk.

Make Global HS

Designates the selected physical disk as a global hot spare.
A global hot spare is part of a pool for all virtual disks
controlled by the controller.
Designates the selected physical disk as a global hot spare.
You can select the hot spare to have enclosure affinity.

Remove HS

Removes a dedicated hot spare from its disk group or a global
hot spare from the global pool of hot spares.