Replace member errors – Dell PowerEdge RAID Controller 6E User Manual

Page 126

Advertising
background image

126

Troubleshooting

Replace Member Errors

Table 7-7 describes issues related to the Replace Member feature.

NOTE:

For more information about the Replace Member features, see "Using

Replace Member and Revertible Hot Spares" on page 37.

A SMART error
occurs during a
Consistency Check
(CC)

Specify how the CC operation must perform when a SMART
error is encountered.

There are two settings, Yes and No. No is the default setting
and allows CC to continue when the first error is encountered.
The Yes setting halts CC when the first error is encountered.

Events are generated in the Event Log when errors are
encountered during CC.

Table 7-7.

Replace Member Operation Errors

Problem

Suggested Solution

The source drive fails
during the Replace
Member operation.

If the source data is available from other drives in the virtual
disk, the rebuild begins automatically on the target drive, using
the data from the other drives.

Target drive fails

If the target drive fails, the Replace Member operation aborts.

Other drives fail

If the target drive fails and the Replace Member operation
aborts but the source data is still available, then the Replace
Member operation continues as Replace Member.

Table 7-6.

SMART Errors (continued)

Problem

Suggested Solution

Dell_PERC6.2_UG.book Page 126 Wednesday, June 24, 2009 6:08 PM

Advertising