Dell PowerEdge RAID Controller 6E User Manual

Page 115

Advertising
background image

Troubleshooting

115

Memory/Battery problems were

detected. The adapter has

recovered, but cached data

was lost. Press any key to

continue.

This message occurs under the following
conditions:

• The adapter detects data in the

controller cache that has not yet been
written to the disk subsystem.

• The controller detects an

Error-Correcting Code (ECC) error
while performing its cache checking
routine during initialization.

• The controller discards the cache rather

than sending it to the disk subsystem
because the data integrity cannot be
guaranteed.

Allow the battery to charge fully to resolve
this problem. If the problem persists, the
battery or adapter DIMM might be faulty;
contact Dell Technical Support.

Firmware is in Fault State

Contact Dell Technical Support.

Firmware version

inconsistency was detected.

The adapter has recovered,

but cached data was lost.

Press any key to continue.

New firmware has been flashed that is
incompatible with the previous version.
The cache contains data that has not been
written to the physical disks and cannot
be recovered. Check data integrity.
You may need to restore the data from
a backup.

Table 7-1.

BIOS Errors and Warnings (continued)

Message

Meaning

Dell_PERC6.2_UG.book Page 115 Wednesday, June 24, 2009 6:08 PM

Advertising