About PERC 6 and CERC 6/i Controllers

Fault Tolerance Features

Table 3-3 lists the features that provide fault tolerance to prevent data loss in
case of a failed physical disk.

Physical Disk Hot Swapping

Hot swapping is the manual replacement of a defective unit in a disk
subsystem while the subsystem is performing its normal functions.

NOTE:

The system backplane or enclosure must support hot swapping for the

PERC 6 and CERC 6/i controllers to support hot swapping.

NOTE:

Replace a physical disk with a new one of the same protocol and

drive technology. For example, only a SAS HDD can replace a SAS HDD;
only a SATA SSD can replace a SATA SSD.

NOTE:

The replacement drive must be of equal or greater capacity than the one it

is replacing.

Table 3-3.

Fault Tolerance Features

Specification

PERC

CERC

Support for SMART

Yes

Yes

Support for Patrol Read

Yes

Yes

Redundant path support

Yes

a

a.

Supported only on PERC 6/E adapters.

N/A

Physical disk failure detection

Automatic Automatic

Physical disk rebuild using hot spares

Automatic Automatic

Parity generation and checking (RAID 5, 50, 6, and 60 only) Yes

Yes

Battery backup of controller cache to protect data

Yes

b

b.

The PERC 6/i adapter supports a BBU on selected systems only. For additional information, see
the documentation that was shipped with the system

N/A

Manual learn cycle mode for battery backup

Yes

N/A

Detection of batteries with low charge after boot up

Yes

N/A