15 Perform the following steps to select the virtual disk parameters:

a

Press <Tab> to move the cursor to the parameters you want
to change.

b

Press the down-arrow key to open the parameters and scroll down the
list of settings.

c

To change the stripe element size, press <Tab> to highlight Stripe
Element Size.

d

Press <Enter> to display the list of stripe element sizes (8 KB, 16 KB,
32 KB, 64 KB, 128 KB, 256 KB, 512 KB, and 1024 KB). Press the
down-arrow key to highlight the desired option and press <Enter>.
The default is 64 KB.

e

If you need to change the read policy, press <Tab> to move the cursor
to Read Policy.

f

Press <Enter> to display the options (No Read Ahead, Read Ahead,
or Adaptive Read Ahead). Press the down-arrow key to highlight the
desired option and press <Enter>.

g

If you need to change the write policy, press <Tab> to move the
cursor to Write Policy.

h

Press <Enter> to display the options (Write-Through, Write Back).
Press the down-arrow key to highlight an option and press <Enter>.

i

Press <Tab> to move the cursor to Force WB with no battery and
press <Enter>. If you chose Write-Through as the write policy, then
this option is not available.

j

Press <Tab> to move the cursor to Initialize and press <Enter>.

CAUTION:

Do not initialize virtual disks when attempting to recreate an existing

configuration.

NOTE:

The initialization performed at this stage is fast initialization.

k

Press <Tab> to move the cursor to Configure HotSpare and press
<Enter>.

NOTE:

The hot spare created at this stage is a dedicated hot spare.