Configuring and Managing RAID

2 Use the arrow keys to highlight Controller # or Disk Group #.
3 Press <F2> to display the actions you can perform.
4 Select Create New VD and press <Enter>.

The Create New VD screen displays. The cursor is on the RAID Levels
option.

5 Press <Enter> to display the possible RAID levels, based on the physical

disks available.

6 Press the down-arrow key to select a RAID level and press <Enter>.
7 Press <Tab> to move the cursor to the list of physical disks.
8 Use the arrow key to highlight a physical disk and press the spacebar,

<Alt>, or <Enter> to select the disk.

9 Select additional disks, if desired.

10 Press <Tab> to move the cursor to the Basic Settings box.
11 Set the virtual disk size in the VD Size field.

The virtual disk size displays in megabyte (MB) format.

NOTE:

For RAID levels 0, 1, 5, and 6 only, you can use part of the available disk

space to create one virtual disk and then use the rest of the disk space to
create another virtual disk or disks.

NOTE:

The minimum virtual disk size is 100 MB.

12 Press <Tab> to access the VD Size field, and type a virtual disk name.
13 Press <Tab> to move the cursor to Advanced Settings.
14 Press the spacebar to make the settings active so that you can

change them.
An X displays beside Advanced Settings. The settings are the stripe
element size, read policy, and write policy. You can also choose advanced
options such as forcing the cache policy to Write-Back, initializing the
virtual disk, and configuring a dedicated hot spare.

The defaults for these parameters are present when the window displays.
You can accept the defaults or change them. For detailed information
about the virtual disk parameters, see "Virtual Disk Parameters and
Descriptions" on page 84.

Dell_PERC6.2_UG.book Page 86 Wednesday, June 24, 2009 6:08 PM