background image

Installing and Configuring Hardware

51

5 Determine whether the Dirty Cache LED on the controller is illuminated.

For location of the LED, see Figure 4-8

If the LED is illuminated, replace the system cover, reconnect the
system to power, turn on the system, and repeat step 1 and step 2.
If the LED is not illuminated, continue with the next step.

6 Disconnect the data cables and battery cable from the PERC 6/i.

Remove any retention mechanism, such as a bracket screw, that might be
holding the PERC 6/i in the system, and gently lift the controller from the
system’s PCI-E slot.

Figure 4-8.

Removing the PERC 6/i Adapter