Dell POWEREDGE 1950 User Manual

Page 18

Advertising
background image

18

About Your System

E1211

ROMB Batt

RAID battery is either missing,
bad, or unable to recharge due to
thermal issues.

Reseat the RAID battery
connector. See "RAID Battery" on
page 60, and
"Troubleshooting
System Cooling Problems" on
page 101.

E1229

CPU # VCORE

Processor # VCORE voltage
regulator has failed.

See "Getting Help" on page 125.

E1310

RPM Fan ##

RPM of specified cooling fan is
out of acceptable operating range.

See "Troubleshooting System
Cooling Problems" on page 101.

E1311

RPM Fan Mod #x

RPM of fan x in the # module is
out of acceptable operating range.

See "Troubleshooting System
Cooling Problems" on page 101.

E1313

Fan Redundancy

The system is no longer fan-
redundant. Another fan failure will
put the system at risk of over-
heating.

Check control panel LCD for
additional scrolling messages. See
"Troubleshooting System Cooling
Problems" on page 101.

E1410

CPU # IERR

Specified microprocessor is
reporting an internal error.

See your system’s "Information
Update Tech Sheet" located on
support.dell.com for the most
current system information. If the
problem persists, see "Getting
Help" on page 125.

E1414

CPU # Thermtrip

Specified microprocessor is out of
acceptable temperature range and
has halted operation.

See "Troubleshooting System
Cooling Problems" on page 101. If
the problem persists, ensure that
the microprocessor heat sinks are
properly installed. See
"Troubleshooting the
Microprocessors" on page 108.

NOTE:

The LCD continues to

display this message until the
system’s power cord is
disconnected and reconnected to
the AC power source, or the SEL
is cleared using either Server
Assistant or the BMC
Management Utility. See the Dell
OpenManage Baseboard
Management Controller User’s
Guide
for information about these
utilities.

Table 1-7.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions