Dell POWEREDGE 1950 User Manual
Page 20
20
About Your System
E1624
PS Redundancy
The power supply subsystem is no 
longer redundant. If the last supply 
fails, the system will go down.
See "Troubleshooting Power 
Supplies" on page 100.
E1710
I/O Channel Chk
The system BIOS has reported an 
I/O channel check.
See "Getting Help" on page 125.
E1711
PCI PERR B## D##
F##
PCI PERR Slot #
The system BIOS has reported a 
PCI parity error on a component 
that resides in PCI configuration 
space at bus ##, device ##, 
function ##.
The system BIOS has reported a 
PCI parity error on a component 
that resides in the specified PCI 
slot.
Remove and reseat the PCI 
expansion cards. If the problem 
persists, see "Troubleshooting 
Expansion Cards" on page 107.
If the problem persists, the riser 
card or system board is faulty. See 
"Getting Help" on page 125.
E1712
PCI SERR B## D##
F##
PCI SERR Slot #
The system BIOS has reported a 
PCI system error on a component 
that resides in PCI configuration 
space at bus ##, device ##, 
function ##.
The system BIOS has reported a 
PCI system error on a component 
that resides in the specified slot.
Remove and reseat the PCI 
expansion cards. If the problem 
persists, see "Getting Help" on 
page 125.
If the problem persists, the riser 
card or system board is faulty. See 
"Getting Help" on page 125.
E1714
Unknown Err
The system BIOS has determined 
that there has been an error in the 
system, but is unable to determine 
its origin.
See "Getting Help" on page 125.
E171F
PCIE Fatal Err
B## D## F##
PCIE Fatal Err
Slot #
The system BIOS has reported a 
PCIe fatal error on a component 
that resides in PCI configuration 
space at bus ##, device ##, 
function ##.
The system BIOS has reported a 
PCIe fatal error on a component 
that resides in the specified slot.
Remove and reseat the PCI 
expansion cards. If the problem 
persists, see "Troubleshooting 
Expansion Cards" on page 107.
If the problem persists, the riser 
card or system board is faulty. See 
"Getting Help" on page 125.
E1810
HDD ## Fault
The SAS subsystem has 
determined that hard drive ## has 
experienced a fault.
See "Troubleshooting a Hard 
Drive" on page 104.
Table 1-7.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions