27

General failure

The operating system is unable to carry
out the command.

This message is usually followed by
specific information. Note the
information, and take the appropriate
action to resolve the problem.

Invalid NVRAM

configuration, Resource

Re-allocated

System detected and corrected a
resource conflict.

No action is required.

Keyboard Controller

failure

Faulty keyboard controller; faulty
system board

See "Getting Help" on page 125.

Manufacturing mode

detected

System is in manufacturing mode.

Reboot to take the system out of
manufacturing mode.

MEMBIST failure - The

following DIMM/rank has

been disabled by BIOS:

DIMM x Rank y

Faulty memory module(s).

See "Troubleshooting System Memory"
on page 102.

Memory address line

failure at address, read

value expecting value

Faulty or improperly installed memory
modules.

See "Troubleshooting System Memory"
on page 102.

Memory double word logic

failure at address, read

value expecting value

Memory odd/even logic

failure at address, read

value expecting value

Memory write/read failure

at address, read value

expecting value

Memory tests terminated by

keystroke.

POST memory test terminated by
pressing the spacebar.

Information only.

No boot device available

Faulty or missing optical drive
subsystem, hard drive, or hard-drive
subsystem, or no boot disk in drive A.

Use a CD or hard drive. If the problem
persists, see "Troubleshooting an Optical
Drive" on page 103 and "T
roubleshooting
a Hard Drive" on page 104.
See "Using
the System Setup Program" on page 31
for information on setting the order of
boot devices.

Table 1-8.

System Messages (continued)

Message

Causes

Corrective Actions