background image

22

About Your System

E2016

Int Controller

Interrupt controller failure.

See "Getting Help" on page 125.

E2017

Timer Fail

Timer refresh failure.

See "Getting Help" on page 125.

E2018

Prog Timer

Programmable interval timer error. See "Getting Help" on page 125.

E2019

Parity Error

Parity error.

See "Getting Help" on page 125.

E201A

SIO Err

SIO failure.

See "Getting Help" on page 125.

E201B

Kybd Controller

Keyboard controller failure.

See "Getting Help" on page 125.

E201C

SMI Init

System management interrupt
(SMI) initialization failure.

See "Getting Help" on page 125.

E201D

Shutdown Test

BIOS shutdown test failure.

See "Getting Help" on page 125.

E201E

POST Mem Test

BIOS POST memory test failure.

See "Troubleshooting System
Memory" on page 102. If the
problem persists, see "Getting
Help" on page 125.

E201F

DRAC Config

Dell remote access controller
(DRAC) configuration failure.

Check for specific error messages.

Ensure that DRAC cables and
connectors are properly seated. If
the problem persists, see your
DRAC documentation.

E2020

CPU Config

CPU configuration failure.

Check for specific error messages.

E2021

Memory

Population

Incorrect memory configuration.
Memory population order
incorrect.

Check for specific error messages.
See "Troubleshooting System
Memory" on page 102.

E2022

POST Fail

General failure after video.

Check for specific error messages.

E2110

MBE Crd # DIMM ##

& ##

One of the DIMMs in the set
implicated by "## & ##" has had a
memory multi-bit error (MBE). If
no memory card is present, the
"Crd #" string is left out of the
message.

See "Troubleshooting System
Memory" on page 102.

Table 1-7.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions