16

Features

CAUTION:

The BIOS Configuration Utility (<CTRL><R>) pauses, and prompts for

action, for the degraded virtual disk(s), if a "pause if degraded" option is enabled

in the BIOS Configuration Utility (<CTRL><R>).

CAUTION:

After the migration occurs, make sure that all of the physical disks

have been migrated and are present in the appropriate virtual disks.

Virtual Disk RAID Levels

Virtual disks can be created at different RAID levels.

Virtual Disk Transformation

Virtual disk transformation can consist of:

• Capacity expansion, using OCE/Reconfigure (to allocate additional virtual

disk space on the original physical disks or after additional physical disks

are added).

• Rebuilding (rebuilding data on a virtual disk consists of using an available

hot spare or backup physical disk).

Read, Write, and Cache Policy

Table 2-1 indicates the read, write, and cache policies that are supported by

the PERC S110 adapter.

CAUTION:

The current default for Write-Cache mode enablement is

Write Through, No Read Ahead (WT, NRA). To enable Write Back (WB), a UPS is
recommended.

Table 2-1. Read, Write, and Cache Policy for the PERC S110

Category

Supported by PERC S110 adapter

Cache Settings

Yes

Read Ahead/Write Back

Yes

No Read Ahead/Write Back

Yes

Read Ahead/Write Through

Yes

No Read Ahead/Write Through

Yes

A5_bk0.book Page 16 Thursday, May 29, 2014 11:37 AM