Troubleshooting

41

2 Check Virtual Disks and determine if the bootable Non-RAID virtual

disk is no longer in the first position.

3 Use the Swap Two Virtual Disks option to swap the virtual disks and place

the bootable Non-RAID virtual disk in the first position of the

Virtual

Disks field.

The PERC BIOS Configuration Option does not Display

The PERC S110 mode is Set Incorrectly in the System BIOS
See "Controller mode is set Incorrectly at System Setup" on page 39 for the correct

SATA Setting.

Warning Messages: Dell Inc. PERC S110 Adapter

BIOS Screen

The Dell Inc. PERC S110 Controller BIOS screen is one of the first screens

to appear during your system’s boot sequence. If the system’s virtual disks

were in Normal or Ready status before a system boot, the boot sequence

continues normally to the Microsoft Windows

Server 2008 operating system.

But, if a virtual disk is in Degraded or Failed status, or if specific options in

the Controller Options field were changed previously at the PERC BIOS

Configuration Utility, the following warning messages appear during the boot

sequence. For other issues, see "Other Errors Appearing on the BIOS" on

page 44.

WARNING: Found Virtual Disks that are Degraded

This warning message appears when at least one virtual disk is in a Degraded

state and Pause if Degraded is set to ON at the PERC BIOS Configuration

Utility.
The following message appears after the warning is displayed:

--- Press <Enter> to continue, or <CTRL><R> to enter

setup ---

Press <Enter> to allow the operating system to continue with the boot

sequence, or press <CTRL><R> to enter into the PERC BIOS

Configuration Utility to investigate the cause of the Degraded virtual disk.