A dedicated hot spare fails, The wrong physical disk was removed – Dell PowerEdge RAID Controller S110 User Manual

Page 52

Advertising
background image

50

Troubleshooting

A Dedicated Hot Spare Fails

The controller cannot communicate with the hot spare

• Check that the cable from the controller to the physical disk is connected

properly.

• Make sure that the physical disk is still assigned as a global or dedicated

hot spare.

• Check if the physical disk assigned as the hot spare has failed.

The dedicated spare is not visible in the PERC BIOS Configuration Utility or

is offline.

The Wrong Physical Disk was Removed

A physical disk has been removed from a virtual disk

The removal of one physical disk from a virtual disk causes:

• A Volume or RAID 0 virtual disk to change to Failed status.
• A RAID 1 and RAID 5 virtual disk to change to

Degraded status.

• A RAID 10 virtual disk to change to

Degraded status (when a physical disk

is removed from one of the mirrored sets).

Re-insert the removed physical disk and perform a Rescan of the virtual disk.

A5_bk0.book Page 50 Thursday, May 29, 2014 11:37 AM

Advertising