RAID Configuration and Management

Before you Begin

• At any point in this procedure, return to a prior state by pressing <Esc>.
• A maximum of eight virtual disks can be created with the PERC BIOS

Configuration

Utility.

NOTE:

Mixing of RAID levels is not allowed on same physical disk(s).

NOTE:

The Create Virtual Disk operation is not selectable when there is no

available capacity on the physical disks.

1 Power-up the system to start booting.
2 When prompted, press the <Ctrl><R> keys to access the PERC BIOS

Configuration Utility.

3 At the Main Menu field, use the arrow keys to select Create Virtual

Disk. Press <Enter>.

4 At the Physical Disks field, select the physical disk(s) on which to create

a virtual disk:

a

For each physical disk, press the <Insert> key to select the physical

disk. (The physical disks can be inserted in any order.)

b

After selecting the physical disk(s) to be included in the virtual disk,

press <Enter>.

5 At the User Input field, use the arrow keys to select a virtual disk type

(RAID level). Press <Enter>. (Only the virtual disk types that can be

created with the selected physical disk(s) that are indicated; they are

highlighted in white text).

6 If hot spares are applicable:

a

At the User Input field, use the arrow keys to select a dedicated hot

spare. Press <Enter>.

NOTE:

A hot spare can be assigned after a virtual disk is created, by selecting

the Manage Hot Spare(s) option.

b

At the Physical Disks field, select the physical disk to use as a hot

spare (if applicable). Press <Insert> to select it.

c

Press <Enter> to add the hot spare. Press the <C> key to confirm

the change.

A5_bk0.book Page 28 Thursday, May 29, 2014 11:37 AM