Troubleshooting Your System

159

CAUTION:

If troubleshooting a power supply mismatch error, replace

only the

power supply with the flashing indicator. Swapping the opposite power supply to
make a matched pair can result in an error condition and unexpected system
shutdown. To change from a High Output configuration to an Energy Smart
configuration or vice versa, you must power down the system.

2 Reseat the power supply by removing and reinstalling it. See "Removing a

Power Supply" and "Replacing a Power Supply."

NOTE:

After installing a power supply, allow several seconds for the system

to recognize the power supply and to determine if it is working properly. The
status indicator turns green to signify that the power supply is functioning
properly.

If the problem persists, replace the faulty power supply with the same type
of power supply.

3 If the problem persists, see "Getting Help."

Troubleshooting System Cooling Problems

CAUTION:

Many repairs may only be done by a certified service technician. You

should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.

Ensure that none of the following conditions exist:

System cover, cooling shroud, drive blank, power supply blank (in single
power supply configurations), or front or back filler panel is removed.

FAN5 blank or heat sink blank is removed in single-processor
configurations.

The expansion card installation guidelines have not been followed. See
"Expansion Card Installation Guidelines."