Table 1-1. lcd status messages – Dell POWEREDGE R710 User Manual

Page 24

Advertising
background image

24

About Your System

Table 1-1.

LCD Status Messages

Code

Text

Cause

Corrective Actions

E1000

Failsafe

voltage

error.

Contact

support.

Check the system event log
for critical failure events.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help."

E1114

Ambient Temp

exceeds

allowed

range.

Ambient temperature has a
reached a point outside of
the allowed range.

See "Troubleshooting
System Cooling
Problems."

E1116

Memory

disabled,

temp above

range. Power

cycle AC.

Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.

Remove AC power to the
system for 10 seconds and
restart the system.

See "Troubleshooting
System Cooling
Problems." If the problem
persists, see "Getting
Help."

E1210

Motherboard

battery

failure.

Check

battery.

CMOS battery is missing or
the voltage is outside of the
allowable range.

See "Troubleshooting the
System Battery."

E1211

RAID

Controller

battery

failure.

Check

battery.

RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.

Reseat the RAID battery
connector. See "Installing
a RAID Battery" an
d
"Troubleshooting System
Cooling Problems."

E1216

3.3V

Regulator

failure.

Reseat PCIe

cards.

3.3V voltage regulator has
failed.

Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards."

Advertising