Dell PowerEdge C5230 User Manual
Page 89

Using the System Setup Program
89
WARN_MIRROR_
DISABLE_MINOR_
RAS_DISABLED
01h
X
X
X
X
Unable to enable
Mirror mode
because ECC is
disabled. Switch to
independent
channel mode. (2)
WARN_MIRROR_
DISABLE_MINOR_
MISMATCH
02h
X
X
X
X
Mismatched
DIMM pairs found
accross channels.
Switch to
independent
channel mode.
WARN_MIRROR_
DISABLE_MINOR_
MEMTEST
03h
X
X
X
X
Mirror mode was
disabled due to
memory test
failure
WARN_MEM_
LIMIT
0Dh
X
X
X
X
IMC memory
decode limit was
reached before all
memory could be
allocated.
WARN_INTERLEA
VE_FAILURE
0Eh
Interleave mode
failure
WARN_SAD_
RULES_
EXCEEDED
01h
X
X
X
X
Number of SAD
rules exeeds
WARN_TAD_RULE
S_EXCEEDED
02h
NOD
E
X
X
X
Number of TAD
rules exeeds
WARN_RIR_RULE
S_EXCEEDED
03h
NOD
E
CH
X
X
Number of RIR
rules exeeds
WARN_TAD_OFFS
ET_NEGATIVE
04h
NOD
E
X
X
X
Negative TAD
offset
Table 2-16. MRC Warning Code
Warning
Major
Code
Minor
Code
Data (DWord)
Descriptions
31:16
15:0
31:24 23:16
15:8
7:0