Dell PowerEdge C5230 User Manual
Page 90
Advertising

90
Using the System Setup Program
WARN_TAD_
LIMIT_ERROR
05h
NODE
X
X
X
TAD Limit > SAD
Limit
WARN_SPARE_DIS
ABLE
10h
X
X
X
X
Unable to enable
Spare mode
because ECC is
disabled. Switch to
independent
channel mode. (2)
Mismatched IMM
pairs found accross
channels. Switch
to independent
channel mode.
WARN_PTRLSCRB
_DISABLE
11h
TBD: not
currently in use.
WARN_UNUSED_
MEMORY
12h
NODE
CH
X
X
Unused memory is
populated on
channel 2 in
Lockstep or
Mirroring
mode.
WARN_UNUSED_
MEM
ORY_MIRROR
01h
NODE
2
X
X
Unused memory is
populated on
channel 2 in
mirror mode
WARN_UNUSED_
MEM
ORY_LOCKSTEP
02h
NODE
2
X
X
Unused memory is
populated on
channel 2 in
Lockstep mode
Table 2-16. MRC Warning Code
Warning
Major
Code
Minor
Code
Data (DWord)
Descriptions
31:16
15:0
31:24 23:16
15:8
7:0
Advertising