,QWHUUXSW$VVLJQPHQWV

350MHZ

*

Microprocessor
speed

Install jumper if the microprocessor’s
internal speed is 350 MHz; otherwise, the
jumper should not be installed.

333MHZ

*

Microprocessor
speed

Install jumper if the microprocessor’s
internal speed is 333 MHz; otherwise, the
jumper should not be installed.

300MHZ

*

Microprocessor
speed

Reserved. Jumper not installed (default).

266MHZ

*

Microprocessor
speed

Install jumper if the microprocessor’s
internal speed is 266 MHz; otherwise, the
jumper should not be installed.

BUS66M

External system
clock

Install jumper to set the external system
clock speed at 66 MHz; otherwise, the
external system clock speed operates at
100 MHz (default).

BIOS

Reserved

Jumper not installed (default).

PSWD Password

enable or disable

Install to enable the password feature
(default).

7DEOH  ,QWHUUXSW $VVLJQPHQWV

,54 /LQH

8VHG %\$YDLODEOH

IRQ0

Generated by system timer.

IRQ1

Generated by keyboard controller.

IRQ2

Generated internally by interrupt controller to enable IRQ8
through IRQ15.

IRQ3

Generated by super I/O controller to indicate that the device con-
nected to the serial port (COM2 or COM4) requires service.

IRQ4

Generated by super I/O controller to indicate that the device con-
nected to the serial port (COM1 or COM3) requires service.

IRQ5

Available for use by an expansion card.

IRQ6

Generated by super I/O controller to indicate that diskette or tape
drive requires service.

IRQ7

Generated by super I/O controller to indicate that device con-
nected to parallel port requires service.

IRQ8

Generated by RTC alarm event.

7DEOH  6\VWHP%RDUG -XPSHU 'HVFULSWLRQV FRQWLQXHG

-XPSHU

'HVFULSWLRQ

6HWWLQJV

* One set of speed jumpers must have a jumper plug installed; otherwise, the system