Detex V50 EE User Manual

Page 18

Advertising
background image

104832 Page 18

1 2

POWER REQUIREMENT:

.5 AMPS @ 24 VDC

Factory
installed

jumper

The key cylinder arming switch must be set to "OFF". To prevent the alarm from

sounding during installation, attach battery AFTER main power is applied.

wer is applied.

Delayed Egress Device requires a connection to the Fire Alarm System.

The fire alarm connection needs to be made

Externally at the Power Supply.

During a fire alarm condition the delayed egress will be by-passed.

MAIN POWER CONNECTION: (1 AND 2)

See Power Supply instructions

DETEX REQUIRES USING THE FIRE ALARM

CONNECTION IN THE POWER SUPPLY:

CLOSED

connection is provided to the fire alarm system when

not in-alarm and OPEN when in-alarm. See power supply

instructions for details.

REMOTE BY-PASS: (5 AND 6)

Connect normally open (N.O.) contact.

When the contact is closed momentarily, this will allow the

door to open without the alarm sounding. The unit will

automatically re-arm in 15 seconds after the door is closed

(three quick audible beeps).

BY-PASS RELAY: (7,8 AND 9) DRY contact output.

The BY-PASS relay is energized when the unit is disarmed by

the KEY or REMOTE BY-PASS to indicate to a remote indicator

that the door is not armed.

ALARM RELAY: (10, 11 AND 12) DRY contact output.

The ALARM relay is energized when the unit is sounding its

alarm to indicate to a remote indicator that an unauthorized

exit has been attempted.

STATUS INDICATOR (SLIDE SWITCH)

ON: Green LED blinks every three seconds

when the unit is disarmed.

Red LED blinks every three seconds

when the unit is armed.

OFF: No status indication

9V Alkaline

Battery

+RED

-BLK

OBSERVE

POLARITY

24VDC

POWER SUPPLY

RED +24V

BLACK GROUND

Status

indicator

switch

Dis Lo Bat switch:

To disable the low-battery

indication, slide "DisLoBat"

switch to 'ON'

Removable

Terminal Block

1 2 3 4 5 6 7 8 9 101112

EE ELECTRICAL OPTIONS

L9= Less 9V battery

SI= Status Indicator