EFCO 8800 Series Assembly Instructions Vol.5 User Manual

Page 33

Advertising
background image

EFCO 2009

Page 33

Series 8700 / 8800 Unitized Curtain Wall Assembly Instructions - Volume 5

Section 23 - SSG Vent Unit Glazing at Stack Sill : C. Adapter Installation

Figure 48

HEAD

SILL

9. Slide the WS00 vent surround gasket into the 17A6 adapters that will be applied to the intermediate horizontals at the head of the concealed vent opening.

Cut the WS00 gasket about 1/4” longer than the 17A6 adapter that will be applied at the head of the vent opening. See Figures 49 through 52 on page 34.

10. Roll the 17A6 adapter into the isolators in the intermediate horizontals at the head and sill of the vent opening. Crowd the WS00 gasket at the head between

the vertical fin bar adapters as the adapter is inserted in place. Center the WS00 gasket in the opening at the sill of the vent opening.

11. Insert HS32 setting blocks between the 17A6 adapter at the head of the vent opening and the upper lite of glazing at quarter points or as directed in the final

approved shop drawings. See Figures 49 through 52 on page 34.

12. Insert WA07 vent bulb gasket into each jamb on each side of the vent opening. Cut the WA07 gasket so that it butts into the 17A6 adapter at the head and sill

of the vent opening. See Figures 49 through 52 on page 34.

Slide WS00 gasket into 17A6 and
apply 17A6 fin bar to the horizontals at
the head and sill of the vent opening.
See Figures 49 - 52 on Page 34.

Insert HS32
setting blocks.

Insert WA07 vent bulb gasket

into each jamb on each side of

the vent opening. See Figures

46 - 52 on page 34.

Concealed Vent

opening

Advertising
This manual is related to the following products: