Section 30 - hardware mounting on unit frame – EFCO 8800 Series Assembly Instructions Vol.5 User Manual

Page 73

Advertising
background image

EFCO 2009

Page 73

Series 8700 / 8800 Unitized Curtain Wall Assembly Instructions - Volume 5

Figure 181

Section 30 - Hardware Mounting On Unit Frame

1. Measure and mark all centerline locations for the keeps and the snubbers. Refer to the final approved shop drawings and the factory order for locations.
2. Apply the snubbers at the head of the vent opening by inserting the tab of each snubber into the groove in the hardware reglet of the horizontal and rotate

into position. Align the snubbers, centered on the marked centerline locations and tighten the pinning screw with an Allen wrench. The number and location
of snubbers will vary depending on vent size and design pressure. Snubbers will not be required for all vent configurations. Refer to the final approved shop
drawings and the factory order for quantities and locations. See Figures 182 below, and 185-187 on page 74.

3. Apply the keepers at the jambs and sill of the vent opening by inserting the tab of each keeper into the groove in the hardware reglet of the jamb adapters

and the sill and rotate into position. Align the keepers, centered on the marked centerline locations and tighten the pinning screw with an Allen wrench. The
number and location of keepers will vary depending on vent size and design pressure. Keepers will not be required at the jambs for all vent configurations.
Refer to the final approved shop drawings and the factory order for quantities and locations. See Figures 183 and 184 below, and 188-189 on page 74.

HEAD

SILL

Figure 182

Figure 183

Figure 184

Adjustable Snubbers

Adjustable Keepers

Adjustable Keepers

Adjustable Keeper

Adjustable Snubber