Series 8700 / 8800 Unitized Curtain Wall Assembly Instructions - Volume 5

Section 24 - Captured Vent Unit Glazing at Fixed Horizontal : A. Temporary Glazing Locators

Figure 58

1. Apply two temporary glazing locators (KV03 and KV04) with isolators and setting blocks at approximate quarter points at the sill and intermediate horizontal

locations.

2. Refer to Volume 2, page 20 and 21 of the S-8000 Unitized Curtain Wall Assembly Instructions for assembly details and notes.

Temporary Glazing

Locators (KV03)

Temporary Glazing

Locators (KV04)

HEAD

SILL

Concealed Vent

opening

Intermediate

Horizontal

Stack Sill

Stack Sill

Concealed Vent Head

KV03

KV04