EFCO 8800 Series Assembly Instructions Vol.5 User Manual

Page 88

Advertising
background image

EFCO 2009

Page 88

Series 8700 / 8800 Unitized Curtain Wall Assembly Instructions - Volume 5

Section 32 - Mounting Vent Assembly Into Unit Frame

20. With the vent propped open for access, attach the Allen keyed release limit arm track to the vent sash and the mounting bracket to the jamb adapter with (4)

STT5 fasteners into the pre-drilled holes provided to each jamb sash and each jamb adapter.

21. Check the operation of the vent and lock hardware to ensure the required hold-open is not exceeded and the vent locks properly. Adjust the keepers and

snubbers if required for alignment with the lock pawls and snubbers on the unit frame. Check for proper closing compression and adjust the keepers if
required.

Figure 228

Figure 229

Figure 230

Attach Allen keyed release limit arm to
each jamb sash and each jamb adapter.

STT5

STT5

Allen Key Release

Limit Arm

Allen Keyed
Release Limit Arm

Adjustable Keeper

Adjust the closing compression by loosening
the adjustment screw of the keeper and sliding
the lock inward or outward as required.

Limit Arm Track

Jamb Adapter

Vent Sash

Mounting Bracket