B

ATTERY

L

IFE

The NiMH battery powering the battery-operated probe has high energy density

for maximum operating time between charges, but also has a significant self-

discharge characteristic. When the probe is stored for longer than a week or two,

the battery will discharge even though not in use. Leaving the battery in a

discharged condition for long periods of time may result in reduced battery life.

For optimum testing time, charge the battery before use.

The battery charger is microprocessor controlled to charge the battery in the

fastest possible manner. When the charger senses that the battery is fully

charged, the charging current drops to a maintenance level. This level is

sufficient to maintain the battery fully charged without causing battery damage. It

is acceptable to leave the probe connected to the battery charger for extended

periods of time.

With proper care, the battery should last two to three years. Follow these

recommendations to ensure maximum battery life and optimum testing

performance:

Set the power switch on the probe to the OFF position when the probe

is not in use. Leaving the power switch in the ON position for extended

periods of time will damage the battery. When the battery is

discharged, the flashing power ON indicator will not function.

When possible, leave the probe connected to the battery charger, and

the battery charger connected to the mains electrical supply (charger

operating). The battery charger status indicators will show CHARGER

ON and COMPLETE when the battery is on a maintenance charge.

Operate the probe only within the optimum operating temperature

range of +20

º

C to +30

º

C (+68

º

F to +86

º

F). Although NiMH batteries

are rated for operation in temperatures from -20

º

C to +65

º

C

(-4

º

F to +140

º

F), operating the probe at temperature extremes

reduces the operating time of the batteries.

Make sure the battery is fully charged before resuming operation. The

battery does not require periodic deep discharges to reverse the effect

caused by repeated shallow discharges, but undercharging can reduce

battery capacity.