Jumper Name Pins System Results
J1E7: BIOS

Default

1 -

2

These pins should have a jumper in place for normal

system operation (Default)

2 -

3

If these pins are jumpered with AC power plugged, the

BIOS settings are cleared within five seconds. These

pins should not be jumpered for normal operation.

J1E8:

Password

Clear

1 -

2

These pins should have a jumper in place for normal

system operation (Default)

2 -

3

If these pins are jumpered, administrator and user

passwords are cleared within 5 – 10 seconds after the

system is powered on. These pins should not be jumpered

for normal operation.

J1D4: BIOS

Recover

1 -

2

These pins should have a jumper in place for normal

system operation (Default)

2 -

3

Since the main system BIOS will not boot with these pins

jumpered, the system can only boot from EFI-bootable

recovery media with the recovery BIOS image.

J1H2: BMC

Force

Update

1 -

2

Integrated BMC Firmware Force Update Mode – Disabled

(Default)

2 -

3

Integrated BMC Firmware Force Update Mode –Enabled

See Section 6.1, “BIOS Defaults and Password Clear Usage Procedure” in the S5520UR