4 installing a hardware raid module – Kontron NSN2U IP Network Server User Manual

Page 44

Advertising
background image

43

9. If this is the last task you are performing inside the chassis, replace the top

front cover.

4.4 Installing a Hardware RAID Module

Hard disk drives are not supported on the NSN2U server by default. One of two

separately-orderable controller options is required. Hardware RAID support requires a

SAS/SATA hardware RAID module, which is described in this section. If basic, non-RAID

support is all that your solution requires, then the SAS/SATA control module is

adequate. See Section 4.3, “Installing a Hardware RAID Module“, if basic support is

what you want.

Figure 31
shows the SAS/SATA hardware RAID module, which provides SAS/SATA RAID

functionality for the server using an LSI Logic LSISAS1078* hardware RAID controller

(“B”). The module’s interface to the baseboard is through a PCI Express bus flex

circuit cable (“A”) to the bridge board. The SAS/SATA hardware RAID module is located

in the front left of the chassis between the power supply system and the SAS/SATA

backplane board. The module’s gold edge connector (“C”) mates with the SAS/SATA

backplane board.

Figure 31. SAS/SATA Hardware RAID Module

Before you can install the SAS/SATA hardware RAID module, you need to remove the

bracket for the 60mm PCI fans. The PCIe flex circuit cable that connects the SAS/SATA

hardware RAID module to the bridge board for baseboard connectivity goes under this

bracket. There is also a protective sheet metal cover that sits over the SAS/SATA

hardware RAID module and this has to come off also before the module can be installed.

1. Remove the front chassis cover. For instructions, see “Removing the Front

Cover” in Section 3.2.

2. Unscrew the large screw at the back of the sheet metal bracket that holds the

60mm PCI fan set. (Figure 30, “A”)

Slide the whole fan assembly up and backwards to disengage the front guide pins

from the chassis base. (“B”)

3. Rest the fan assembly on the front of the server. (You do not need to remove

the fans or unplug the power connector.)

4. If you are using an IBBU on the SAS/SATA hardware RAID module, install it now.

For instructions see Section 4.5 “Installing a RAID Intelligent Battery Backup

Unit (IBBU)”

Advertising