33

Opts menu

Target

See Targeting the pedestals on page 34 for information on using this function to
target the pedestals.

Return

Select RETURN in the OPTS menu to go back to the workspace without performing either an
Enable or Target command.

Enable a camera

If a camera is offline (black camera select button) then it is likely that there is a problem with the
camera or system setup. Check that the camera is powered on and that all cabling to the camera is
connected correctly. If the camera does not come online, further investigations are necessary.

If the head is in manual mode (grey camera select button) it must be enabled from the controller
before the camera can be controlled. Make sure that the head is powered On. The head will
automatically switch to Robotic (auto) mode if necessary. Select the camera on the touch-screen or
control panel and then select OPTS>ENABLE to bring the camera online.

If the pedestal is in manual mode (brown camera select button) it must be switched to Robotic (auto)
mode and then enabled from the controller before it can be controlled. Make sure that the pedestal
is powered On and switched to Robotic mode, then select the camera on the touch-screen or control
panel and then select OPTS>ENABLE to bring the camera online.

NOTE:

The camera must be re-targeted after enabling, when switching the
pedestal from manual to automatic mode. See Targeting a pedestal
on page 34. A head mounted on a pedestal can be placed into
manual mode without the need for re-targeting.