Maintenance schedule, Monthly, Yearly – Wine Guardian Ducted Split Wine Cellar Cooling Systems (WGS175) - Manual User Manual

Page 65

Advertising
background image

67

Maintenance Schedule

Monthly

(or quarterly depending on experience with individual cellar)

 Check filter and drain trap – clean if needed.
 Check for noise or vibration.

 Check for short-cycling of the unit – a turning on and off of the compressor unit

more than either (8) times/hour.

Yearly

(in addition to monthly)

 Replace filters if worn or plugged beyond cleaning.
 Check evaporator and condenser coils for dirt – use a vacuum with a brush

attachment to clean the coils.

 Clean condensate pan under the evaporator coil by flushing. Be careful to keep the

drain pans clear of any and all debris.

 Inspect cabinet for corrosion or rusting – clean and paint.
 Inspect for dirt buildup on or inside the unit. Clean unit by vacuuming or wiping it

down.

 Check for loose insulation, fasteners, gaskets or connections.
 Check the wiring connections and integrity or cords.
 Examine ducts for any cracks or breach.
 Check fan and solenoid on humidifier.
 Replace humidifier pad (if used).

Advertising