Humidity too low with optional humidifier


Possible Cause

Solution


Humidifier not operating

Check wiring for loose, broken or frayed

connections

Check humidistat set up

Check for water flow & solenoid valve

operation

Check damper operation


Humidifier operating

Check for water being hot

Check drip pad – replace if scaled

No vapor barrier around cellar

Humidity too high when unit is running but not cooling

Possible Cause

Solution

Compressor not operating

Check and reset high limit switch

Clear blockage of condenser airflow

Ambient temperature is too high

Reduce temperature or draw condenser air

from another space

Humidity too high when the unit is not running

Possible Cause Solution

Unit needs to run to dehumidify

Run unit. Seal openings around doors (gasket and

sweep)

Humidity too high when unit is running and cooling

Possible Cause Solution

Too much moisture in cellar Poor vapor barrier installation
Humidifier malfunction refer to the humidifier
instructions.

Add dehumidifier to surrounding space