INSTALLATION

Precaution:

The following installations should be made by
qualified service personnel or system installers.

Setting the camera switches (only for WV-CSR604)

• To reset the communication parameters to the

factory preset values, for example, when

operating multiple cameras in a daisy chain
connection, set the switches inside the camera
as shown in the table below.

1

.

Disassemble the camera

Confirm the power is turned off.

Remove the screw from inside the hole for the

fall prevention wire. Hold the diecast case

containing the camera and rotate it to the left
as shown below.

Note: Setting of switches while the power is on

may cause a malfunction. Make sure the

power is turned off before setting the

switches.

2. Setting the switches

Set the switches as follows:

Dtp Switches

Switch A: Full duplex (four lines)/Half duplex

(two lines) switch

Switch B: Termination ON/OFF switch
Switch C; Dip switches (become effective when

the power is turned on)

Initialization of soft­

ware communication

parameters

DIPS

OFF Normal Setting

ON

Initial

Settings

Notes:

• Select OFF after resetting the parameters by

selecting ON,

• The factory settings is OFF.

Camera Unit No,

DIP 1 DIP 2

OFF

OFF

01 - 32

OFF

ON

33-64

ON

OFF

65-96

ON

ON

Inhibition

The factory settings for the dip switch 1 and 2 are

OFF both.

- 2 9 -