Channel overview – STIEBEL ELTRON SOM 6 PLUS User Manual

Page 11

Advertising
background image

11

Now the controller is ready for operation with typical settings
to suit the selected system layout.
The settings made in the commissioning menu can be
changed later on in the corresponding adjustment channels.
Additional functions and options can of course be individually
adjusted as well (see chap. 4.2).

Completing the commissioning menu
After the last channel of the commissioning menu has been
adjusted and confirmed, the controller asks for confirmation
of the adjustments.

Î To confirm the adjustments made in the commissioning

menu, press button 3

Confirmation enquiry

Indication of collector temperature

Indicates the current collector temperature.

COL:
Collector temperature
Display range: -40 ... +500 °F

[-40 ... +260 °C]

Indication of tank temperatures

Indicates the current tank temperature.

TST:
Tank temperatures
Display range: -40 ... +500 °F

[-40 ... +260 °C]

Initialization

Indicates the time adjusted in

tDTO, running backwards.

INIT:
ODB initialization active

Filling time

Indicates the time adjusted in

tFLL, running backwards.

FLL:
ODB filling time active

Stabilization

Indicates the time adjusted in

tSTB, running backwards.

STAB:
Stabilization

4.1 Display channels

Note:

The displayed values and adjustment channels

depend on which options and functions have been

selected. Only values and adjustment channels

available for the individual settings selected will

appear in the menu.

Indication of drainback time periods

4. Channel overview