19

For control and service work, the operating mode of the
controller can be manually adjusted. For this purpose, select
the adjustment value

MAN in which the following adjustments

can be made:

Operating mode

Operating mode
OFF : relay off

(flashing) +

Auto : relay in automatic operation
ON : relay on

(flashing) +

+

MAN:
Operating mode Adjustment
range: OFF, Auto, ON
Factory setting: Auto

Language

The menu language can be adjusted in this channel.
dE : German
En : English

LANG:
Language selection
Selection: dE, En
Factory setting: En

Unit

In this adjustment channel, the display unit for temperatures

and temperature differences can be chosen. The unit can be
switched between °C / K and °F / °Ra during operation.

Temperatures and temperature differences in °F and °Ra are

displayed without units. If the indication is set to °C, the units
are displayed with the values.

UNIT:
Temperature unit selection
Selection: °F, °C
Factory setting: °C

Note:
Always adjust the operating mode back to “Auto”
when the control and service work is completed.
Normal operation is not possible in manual mode.

Reset

By using the reset function, all adjustments will be set back
to the factory settings.

Î To initiate a reset, press button 3
Any previous adjustments will be lost. Therefore, initiating
the reset function is always followed by a security enquiry.
Only confirm the security enquiry if you are sure that you wish

to reset all adjustments to the factory settings!

RESE
Reset function

Security enquiry:

Î To confirm the security enquiry, press button 3

Note:
Whenever a reset has been completed, the controller
runs the commissioning menu again (see chap. 3).