Operation and function, 1 push buttons, 2 system monitoring display – STIEBEL ELTRON SOM 6 PLUS User Manual

Page 8

Advertising
background image

8

The system monitoring display consists of three blocks:

channel

display, tool bar and system screen.

The

channel display consists of 2 lines. The upper line is an alpha-

numeric 16-segment display (text display) for displaying channel
names and menu items. In the lower 7-segment display, the
channel values and the adjustment parameters are displayed.
Temperatures are either indicated in °F or °C, whereas
temperature differences are indicated in K or °Ra respectively.

channel display

The additional symbols of the

tool bar indicate the current

system status.

tool bar

2. Operation and function

2.1 Push buttons

The controller is operated via three push buttons below the
display.
Button 1 is used for scrolling forward through the indication
menu or to increase the adjustment values.

Button 2 is used for

scrolling backward and reducing values.

Button 3 is used for

selecting channels and confirming adjustments.
During normal operation, only the display channels are
shown.

Î Scroll through the display channels by pressing buttons

1 and 2

Accessing the adjustment channels:

Î Scroll down in the display menu and press button 1 for

approx. 2 seconds after you have reached the last display
item.

When an

adjustment value is shown on the display,

is

indicated to the right of the channel name.

Î Press button 3 in order to access the adjustment mode

starts flashing.

Î Adjust the value using buttons 1 and 2

Î Briefly press button 3,

permanently appears,the

adjusted value will be saved.

2.2 System monitoring display

system monitoring display

1

3

2

backward

forward

SET

(selection / adjustment mode)

operating control lamp

Status

standard

flashing

relay 1 active

maximum tank temperature exceeded

tank emergency shutdown active

+

collector emergency shutdown active

collector cooling active

system cooling active

tank cooling active

+

holiday cooling function activated

holiday cooling function active

+

collector minimum limitation active
antifreeze function activated

antifreeze function active

manual operation relay 1 ON

+

manual operation relay 1 OFF

sensor defective

Advertising