STIEBEL ELTRON SOM 6 PLUS User Manual

Page 7

Advertising
background image

7

Legend:

Symbol

Specification

x

Channel is available

x*

Channel is available if the corresponding option is activated.

Adjustment Channels
Channel

Description

Factory setting

Page

DT O

x

Switch-on temperature difference

12.0 °Ra [6.0 K]

14

DT F

x

Switch-off temperature difference

8.0 °Ra [4.0 K]

14

DT S

x

Nominal temperature difference

20.0 °Ra [10.0 K]

14

RIS

x

Rise control

4 °Ra [2 K]

14

nMN

x

Minimum pump speed

30 %

14

S MX

x

Maximum tank temperature

140 °F [60 °C]

15

EM

x

Emergency temperature collector

270 °F [130 °C]

15

Emergency temperature collector if ODB is activated:

200 °F [95 °C]

15

OCC

x

Option collector cooling

OFF

16

CMX

x*

Maximum collector temperature

230 °F [110 °C]

16

OSYC

x

Option system cooling

OFF

16

DTCO

x*

Cooling switch-on temperature difference

40.0 °Ra [20.0 K]

16

DTCF

x*

Cooling switch-off temperature difference

30.0 °Ra [15.0 K]

16

OSTC

x

Option tank cooling

OFF

17

OHOL

x*

Option holiday cooling

OFF

17

THOL

x*

Holiday cooling temperature

110 °F [40 °C]

17

OCN

x

Option minimum limitation

OFF

17

CMN

x*

Minimum collector temperature

50 °F [10 °C]

17

OCF

x

Option antifreeze

OFF

17

CFR

x*

Antifreeze temperature

40.0 °F [4.0 °C]

17

OHQM

x

Option energy metering

OFF

18

FMAX

x*

Maximum flow

6.0 l

18

MEDT

x*

Antifreeze type

1

18

MED%

x*

Antifreeze concentration (only if MEDT = propylene or ethylene)

45 %

18

ODB

x

Drainback option

OFF

19

tDTO

x*

ODB switch-on condition - time period

60 s

19

tFLL

x*

ODB filling time

5.0 min

19

tSTB

x*

ODB stabilization time

2.0 min

19

MAN

x

Manual operation R1

Auto

20

LANG

x

Language

En

20

UNIT

x

Temperature unit

°C

20

RESE

x

Reset - back to factory defaults

20

W0020100

Version number

Advertising